WinNUTVersion Win 95 Win 95 OSR2 Win 98 Win 98 2nd edition Win ME Win NT 4 workstation Win NT 4 Server Win 2000 Professional Win XP Win 2003 Server
Windows Vista 32 & 64bit
2.0.0b
untested untested untested untested untested untested untested untested Tested Good
Tested Good Tested Good
2.0.0a untesed untested untested Tested Good untested Tested good (sp6a) untested Tested Good Tested Good Tested good
untested
1.2.1a Tested Good untested untested Tested Good untested untested Tested Good Tested Good Tested Good untested untested
0.45.2c untested untested untested Tested Good untested untested untested Tested Good Tested Good untested untested
0.45.2b untested(2) untested(2) untested(2) Tested Good(2) untested(2) untested(2) untested(2) Tested Good(2) Tested Good(2) untested untested
0.45.2a untested untested(2) untested Tested Good untested untested Tested Good(2) Tested Good untested untested untested
0.44.1c untested untested(2) untested Tested Good untested untested untested Tested Good untested untested untested
0.44.1b untested Tested Good(2) untested Tested Good(1) Tested Good(1) untested untested Tested Good untested untested untested
0.44.1a Tested Good Tested Good(2) untested Tested Good Tested Bad(3) untested Tested Good Tested Good Tested Bad(4) untested untested

Tested Good means that it successfully shutdown the computer when the ups went critical - caveats to this are the number exceptions below
Tested Bad means it failed to shutdown the computer properly - an explaination is in the numbered list below
Foot notes
1 Some programs like Active Desktop don't work well with the forced shutdown in the windows 9x series. In particular ActiveDesktop comes up in safe mode after a forced shutdown. You should just be able to click on the restore button to fix it.
2 This is now a confirmed bug in all versions up to and including 0.45.2b. IP addresses in the upsmon.conf cannot be resolved properly to connect to the machine running upsd. Workaround is to use a DNS resolvable name (can just add the upsd machines name and ip to the c:\windows\hosts or c:\winnt\system32\drivers\etc\hosts file on the windows machine to make it DNS resolvable) and use that name in the upsmon.conf. The next release will have this fixed
3 Using the combination of shutdown and poweroff flags in the exit windows API call cause ME to suspend instead of shutdown
4 Whistler Beta1 blue screened when the UPS went critical - maybe an issue with the beta

Have you run WinNUT against one of the platforms listed as untested? If so let me know () so I can update the list. Thanks!